13) In the junction box where you will install ToggleLinc Primary, identify the Load wire (usually red).
This is the wire that carries power from the switch to the load.
14) Identify the black Traveler wire. If you are unsure, repeat steps 3-6 to measure the voltage and
find the wire measuring 120VAC. This is the wire connected to the Line wire in step 7.
Make sure the electricity is turned off before proceeding.
15) Connect ToggleLinc Primary’s black Line wire to the junction box’s black Traveler wire with a wire
nut (see Fig. 2).
16) Cap the junction box’s red Traveler wire with a wire nut.
17) Connect ToggleLinc Primary’s red Load wire to the junction box’s Load wire with a wire nut.
18) Connect ToggleLinc Primary’s white Neutral wire to the box’s Neutral wires with a wire nut (see
Fig. 3).
19) Connect ToggleLinc Primary’s bare copper Ground wire to the junction box’s Ground wires with a
wire nut (see Fig. 4).
20) Refer to step 6 in Installing ToggleLinc in a Typical 2-Way Circuit to complete installation.
Special Treatment for 4- or More-Way Circuits
If your lighting circuit includes more than two switches controlling a single set of lights, those extra
switches will have four wires connected to them. Two of the wires are Travelers from the preceding
switch, while the other two are Travelers to the next switch in the chain. You will convert the black
Traveler wires to Line wires and replace the old 4-wire switches with ToggleLinc Secondaries.