Insteon Load Controller 220V / 240V 30 Amp, N/O and N/C (2 User Manual

Browse online or download User Manual for Hardware Insteon Load Controller 220V / 240V 30 Amp, N/O and N/C (2. INSTEON Load Controller 220V / 240V 30 Amp, N/O and N/C (2477SA1, 2477SA2) Quick Start User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Page 1 of 2
Rev. 07-16-2012
INSTEON Limited Warranty INSTEON warrants to original consumer of this product for a period of 2 years from date of purchase, this product will be free
from defects in material and workmanship and will perform in substantial conformity with its Owner's Manual. Warranty shall not apply to defects caused by
misuse or neglect.
Protected under U.S. and foreign patents (see www.insteon.com) © Copyright 2012
INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 800-762-7845, www.insteon.com
Installation
1) If you plan to incorporate this with INSTEON-compatible software, you can write down the INSTEON I.D. and the
location of the fixture you’ll be controlling (e.g. 01.F7.G5, water heater)
2) At the circuit breaker or fuse panel, disable the circuit supplying power to the electrical junction box that is wired to
the appliance you wish to control with 240V Load Controller
3) Remove the cover of the junction box and disconnect the two supply lines coming from the circuit breaker,
ensuring that you have ½of bare and clean copper wire on the ends
4) See Figure 1 on the next page to properly connect 240V Load Controller to the load and the junction box. The
Ground wire will not be connected to 240V Load Controller, so cap the ground wires off with a wire nut.
5) Ensure that all connectors are firmly attached and that there is not exposed copper except for the ground wire
6) Enable power to the junction box from the circuit breaker or fuse panel
7) Test that 240V Load Controller is working properly by pressing the Set button to toggle the load on, and then off
Quick Start Guide
INSTEON
®
240V 30 Amp Load Controller (Dual-Band)
Models: 2477SA1 Normally Open Relay
2477SA2Normally Closed Relay
Preparation
Because this device involves high voltage levels, it is
recommended that installation be performed only by a
qualified electrician or by a homeowner who is extremely
knowledgeable and familiar with electrical circuitry. Please
take an extra level of precaution when installing this device.
If you have any questions regarding installation, we suggest
consulting an electrician.
Tools Needed
Phillips and standard screwdrivers
Wire cutter/stripper
Various tools to mount 240V Load Controller to a wall
Introduction
Remotely control your appliances that run on voltages
between 120 and 240 Volts, up to 30 Amps (resistive loads
only).
Using 240V Load Controller
Use the Set button on 240V Load Controller to toggle the load on and off.
Status LED will be solid green when the load is on and solid red when the load is off.
See the following table for the Active LED status:
240V Load Controller Model (SKU #)
Active Status LED
Normally Open Relay (#2477SA1)
Off
Solid green
Normally Closed Relay (#2477SA2)
Off
Solid green
Off
Set button
Status LED
Load Active